C1D2 Rated Explosion Proof Industrial Chillers Designed for Hazardous Environments

250-Ton Water Cooled Low Temp Ammonia Chiller Rated For Class 1 Division 2
250-Ton "Water-Cooled" Ammonia Chiller Rated for Class 1 Division 2 Groups C & D

UL-NNNY Certified Process Chillers for Hazardous Environments

Our custom engineered chiller systems can be designed for Class 1 Division 2 explosion proof hazardous environments using either semi-hermetic or open drive compressor motors. Control panels can be remote mounted or purged and skid-mounted.

Tempest designs to the following ratings: Class 1, Division 2, Groups B, C, and/or D

Hazardous Classifications, Divisions, and Group Rating Information

Hazardous Classification: Defines the GENERAL NATURE OR PROPERTIES of the hazardous material in the surrounding atmosphere

CLASS 1

Flammable gases, vapors, or liquids are present, or may be present in quantities sufficient to produce explosive or ignitable mixtures

CLASS 2

Combustible dusts are present, or may be present in quantities sufficient to produce explosive or ignitable mixtures

CLASS 3

Ignitable fibers or flyings are present, or may be present in quantities sufficient to produce explosive or ignitable mixtures

Hazardous Divisions: Defines the PROBABILITY of the hazardous material being present in an ignitable concentration in the surrounding atmosphere

DIVISION 1

The substance referred to by class has a high probability of producing an explosive or ignitable mixture due to it being present continuously, intermittently, or periodically or from the equipment itself under normal operating conditions

DIVISION 2

The substance referred to by class has a low probability of producing an explosive or ignitable mixture and is present only during abnormal conditions for a short period of time such as a container failure or system breakdown

Hazardous Group: Defines the TYPE of the hazardous material in the surrounding atmosphere

GROUP A

Atmosphere containing acetylene

GROUP B

Atmosphere containing a flammable gas, a flammable liquid produced vapor, or a combustible liquid produced vapor mixed with air that may burn or explode having either a MESG (Maximum Experimental Safe Gap) value less than or equal to 0.45 mm or a MIC (Minimum Igniting Current) ratio less than or equal to 0.40 – such as hydrogen or fuel and combustible process gases containing more than 30% hydrogen by volume – or gases of equivalent hazard such as butadiene, ethylene oxide, propylene oxide, and acrolein

GROUP C

Atmosphere containing a flammable gas, a flammable liquid produced vapor or a combustible liquid-produced vapor whose MESG is greater than 0.75 mm or MIC ratio is greater than 0.40 and less than 0.80 – such as carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl, isoprene, acetaldhyde and ethylene or gases of equivalent hazard

GROUP D

Atmosphere containing flammable gas, flammable liquid produced vapor, or combustible liquid produced vapor mixed with air that may burn or explode, having either a MESG value greater than 0.75 mm or a MIC ratio greater than 0.80 – such as gasoline, acetone, ammonia, benzene, butane, ethanol, hexane, methanol, methane, vinyl chloride, natural gas, naphtha, propane or gases of equivalent hazardĀ 

Examples of Tempest Chillers Designed for Class 1 Division 2 Hazardous Industrial Environments

Low Temperature Ammonia Refrigerant Chiller Rated for Class 1 Division 2 - Tempest
Market: Petrochemical: 250-Ton "Water-Cooled Class 1 Division 2 Ammonia Chiller @ 22F SST
Market: Specialty Chemicals: 150-Ton "Water-Cooled" Class 1 Division 2 Chillers @ -21FSST
Low Temperature Ammonia Refrigerant Chiller Rated for Class 1 Division 2 - Tempest
Market: Petrochemical: 250-Ton "Water-Cooled Class 1 Division 2 Ammonia Chiller @ 22F SST
Market: Specialty Chemicals: 150-Ton "Water-Cooled" Class 1 Division 2 Chillers @ -21FSST
3.8-Ton Low Temp Chiller @-37F Evap for Hydrogen Cooling at Fueling Station
Market: Hydrogen Fueling: 3.8-Ton "Air-Cooled" Class 1 Division 2 Group B Chiller & Pump/Tank Package @ -37 SST
Application: Methane Gas Stream: 7-Ton Chiller/TCU Combo System Rated for Class 1 Division 2 Groups B, C, & D

UL-NNNY C1D2 Rated Industrial Process Chillers

Design Features of a C1D2 Rated UL-NNY Chiller

Tempest Custom Engineered Industrial Chiller Areas of Expertise

Ammonia Industrial Chiller Systems

With 40+ years of ammonia design experience Tempest is an advocate for ammonia refrigeration systems. Ammonia systems are energy efficient at low temperatures, experience increased longevity, and are economically friendly
Ammonia Chillers

Class 1 Division 2 Rated Industrial Chiller Systems

UL-NNNY certified Class 1 Division 2 explosion proof industrial process chillers. Tempest can design to Class 1, Division 2 Groups B, C and/or D.
C1D2 Rated Chiller Systems

Containerized / CONEX Industrial Chiller Systems

Tempest Custom Engineered CONEX Chillers come in ISO-Standard 20FT or 40FT containers. A great option if indoor floor space is limited or an economical mechnical room is needed.
CONEX Chillers

Industrial Chiller & TCU Combo systems

Process applications that require balanced temperature control between -40F and 370F. Tempest can deliver a custom engineered Chiller with an integral TCU circuits or separate TCU skid mounted systems.
Chiller & TCU Combo Systems